Model
PMC
Machine Specifications

Operator Interface Panel:
The PMC is operated through an operator interface panel. The
operator can set the number of pieces, dwell time (if Required), wire length and
start the run.
Malfunction:
The machine will automatically stop and an indicator light will go on if
shear actuation in not completed, or a stall is detected. When the problem
has been solved, the machine may be restarted without losing the logic already
programmed.
Wire Length:
The wire can be measured and cut in lengths in .1 inch increments by
entering the desired length on the operator interface panel. The PMC uses
a digital encoder (riding the wire) so wire length is extremely accurate.
Number of Pieces:
The number of pieces of wire required may be programmed by entering the
desired number on the operator interface panel. The machine will
automatically stop pulling wire when the programmed number of pieces is reached.
Pause:
The Machine may be stopped with the stop switch and restarted with the
resume switch without affecting the programmed length, mark spacing or number of
pieces.
Dwell Time:
Dwell time is microprocessor controlled and may be set in .01second
increments. Dwell time can be used as a base when slaved to machines which
do not have the ability to send a return computer signal.
Automatic Control:
The Machine is provided with a 4-pin receptacle so that a cable from a
cutting and stripping machine may be plugged in and remotely control the
stamping sequence.
Programming Features:
| Stall Detect if the machine detects a stall in the pulling of the wire one-tenth of an inch, the program will immediately shut down preventing compromise of the insulation Pause
between Shear |
Electrical Supply:
The PMC requires 120 volt 60 HZ 10 AMP supply. We can provide for 230
volt 50 HZ at a nominal added cost.
Air Supply:
Supply air should be 100 to 120 PSIG with a water filter at the entrance
to the machine. NO oiler should be used.